An Unbiased View of how HPLC works
An Unbiased View of how HPLC works
Blog Article
An HPLC normally includes two columns: an analytical column, which can be answerable for the separation, and also a guard column that is definitely positioned prior to the analytical column to protect it from contamination.
각각 다른 산업 분야에 대한 자세한 정보 및 다양한 카테고리는 다음 써모 피셔 사이언티픽 학습 센터에서 산업 및 응용 과학 페이지를 확인하세요.
As being a common rule, a two device improve from the polarity index corresponds to an about 10-fold change in a solute’s retention element. Here is a straightforward instance. If a solute’s retention factor, k
物質の電気化学的な性質を利用した検出器。pHの変動や酸化還元電位の変動を用いて測定を行う。
物質にエネルギーを与える(励起)ことにより発光する(蛍光)性質を利用した検出器。一般に選択性が高く高感度で、物質に特異的な検出が可能。蛍光する性質を持たない物質については、その物質を標識することにより検出が可能になる。
The material of our Internet site is usually out there in English and partly in other languages. Choose your chosen language and We are going to show you the articles in that language, if offered.
各種の高速液体クロマトグラフィーの項目にある違いは、カラムの違いである事が多いため、装置はそのままでカラムの変更で行える場合が有る。ただし、誤って不適当な溶媒を通すとカラムを破損することがあるため、切り替えを行う際には注意が必要である。
The running stress within an HPLC is adequately high that we can not inject the sample to the cell stage by inserting a syringe via a septum, as is possible in fuel chromatography. Rather, we inject the sample utilizing a loop injector
The buy of elution of compounds from the column is ruled via the depth of connection with the stationary stage. The eluent While using the separated chemical compounds flows previous the detector.
High-performance liquid chromatography (HPLC) is a robust analytical method for separating high performance liquid chromatography and pinpointing components in a combination. Obtaining accurate and trusted final results calls for very careful interest to each phase of your Evaluation, from sample preparation to info interpretation.
, which happens to be the greater frequent form of HPLC, the stationary phase is nonpolar plus the cellular section is polar. The most typical nonpolar stationary phases use an organochlorosilane the place the R team is surely an n
The realm underneath Each individual peak is proportional to the amount of the corresponding analyte. The information acquisition system allows for the analysis of peak retention moments, peak areas, along with the calculation of analyte concentrations.
Mobile phase impurities: Contaminants while in the cellular section can elute from your column and exhibit up as ghost peaks. Put together click here a clean cell section with high-purity solvents and consider filtering the cell stage prior to use.
In liquid–liquid chromatography the stationary section is usually a liquid movie coated with a packing content, normally 3–10 μm porous silica particles. As the stationary stage may be partially soluble inside the mobile phase, it may well elute, or bleed in the column eventually.